3.Key Use Instructions
1.Backlight Control:
In standby display, short press “▲”key can turn on or turn off the screen backlight, backlight state power off automatically save
2.Clear Current:
In standby display, long press “▲”key about three seconds can clear current,(Note:The load must be empty when clear,otherwise it’s inaccurate)
3.Clear Electric Energy:
In standby display,long press “█”key about three seconds can clear electric energy.
4.Setting Parameters:
In standby display,short press “█”key can switch the menu as follows:
【1】“AH XXX.X”the menu of battery rated capacity setting.
【2】“FU XXX.X”the menu of full power automatically filled voltage
setting.
【3】“HU XXX.X”the menu of high voltage alarm setting.
【4】“LU XXX.X”the menu of low voltage alarm setting.
【5】“HA XXX.X”the menu of high current alarm setting.
Battery rated capacity setting:(1)In standby display, short press █ key,will switch to the menu “AH XXX.X”.
(2)The first digit of the menu parameter will flicker,short press ▲ key at this time digit will increasing one.When the button is not operated within five seconds, it will automatically jump to the next number to flicker.and you short press ▲ key digit will also increasing one.And the like to set up four numbers.
(3)After set up four numbers ,Long press █ key about three seconds (Note: it is not short press) and then release the key can save the parameters.When to save success the screen will flicker two times.
For example:When you want to set the battery rated capacity to be 20AH.You should set this menu parameter of“AH 020.0”,and long press █ key to save parameter is finish.
The battery is full of the highest electric voltage setting:(1)In standby display, short press █ key,and switch to the menu “FU XXX.X”.
(2)The first digit of the menu parameter will flicker,short press ▲ key at this time digit will increasing one.When the button is not operated within five seconds, it will automatically jump to the next number to flicker.and you short press ▲ key digit will also increasing one.And the like to set up four numbers.
(3)After set up four numbers ,Long press █ key about three seconds (Note: it is not short press) and then release the key can save the parameters.When to save success the screen will flicker two times.(Note: This voltage is suggested to be set to 0.2V less than the Coulomb’s voltage when the battery is full and has not pulled out the charger.)
And the like you could setting the parameters of “HU XXX.X”“LU XXX.X”“HA XXX.X”(Not:This three parameters of the factory default is “000.0” ,the factory default is to close this item’s alarm function.)
6.Wiring Instructions
There are three wires in the head of the table, as follows:
【1】The black wire is connected to the battery negative pole.
【2】The Red wire connection power supply positive pole.
【3】The Yellow wire is connected to the battery positive pole.
When the measured voltage range is DC5~90V,the red and yellow wires are connected in parallel to the battery positive pole.As follows:
7.Precautions For Use
【1】The battery discharge ,coulomb shows display positive current.The battery charge ,coulomb shows display negative current. If not,the direction of the sensor is wrong. You show turn the direction of the sensor to another direction.
【2】The newly installed Coulomb needs to clean up the current at an empty load.
【3】The rated capacity of the battery and the maximum electric voltage of the battery must be set up. The newly installed Coulomb needs to charge the battery to full after setting up the parameters,then residual battery power can be displayed normally.